Measurements & diagnostics
Boulogne-Billancourt, Acoustics · Air permeability · Ventilation · EPC · Drone

In Boulogne-Billancourt, ARKENOR carries out the regulatory acceptance measurements of buildings — air permeability (RE2020), acoustics, ventilation, energy performance certificate — as an independent third party, with compliant certificates.

Updated 21 July 2026

Boulogne-Billancourt · Île-de-France

Regulatory measurements & diagnostics in Boulogne-Billancourt.

The most populous commune in the Île-de-France after Paris, Boulogne-Billancourt combines a substantial commercial building stock, mixed-use schemes arising from the conversion of former industrial land and a density that strongly constrains construction sites. At handover, generalised party walls make acoustic insulation towards neighbouring buildings and between dwellings the most frequently disputed point. In Boulogne-Billancourt and across the Hauts-de-Seine we carry out regulatory acceptance measurements, as an independent third party.

Our measurements

Six families of measurements & diagnostics in Boulogne-Billancourt.

RE2020 air permeability testing

QUALIBAT 8711

Airtightness testing (Q4Pa-surf air permeability): an intermediate test at the weathertight-shell stage to correct defects before lining, and a regulatory RE2020 acceptance test on the finished building.

Acceptance acoustic testing

NF EN ISO 16283

Airborne sound insulation (DnT,A / DnT,A,tr), impact sound (L'nT,w), equipment noise and reverberation: verification of the NRA housing requirements and the ERP order, carried out as an independent third party.

RE2020 ventilation airflow testing

QUALIBAT 8741

Functional checking of ventilation systems (airflow rates, pressure drops, ductwork airtightness) required by RE2020 at the handover of new dwellings.

Housing and commercial energy performance certificate (DPE)

certified assessor

Legally binding energy performance certificate (DPE), issued by a certified assessor, for sale, letting and monitoring under the tertiary-sector decree.

Drone aerial inspection

DGAC drone pilot

Inspection of roofs and façades, aerial thermography, photogrammetry and mapping by drone (DGAC-registered drone pilot), on sites that are difficult to access.

Electromagnetic field (EMF) measurements

NF EN 50492

Low frequencies at 50 Hz (electric field kV/m, magnetic field µT) and radiofrequencies from 9 kHz to 300 GHz (V/m), following the UTE/NF C99-132 and ANFR protocols. A criterion recognised in HQE and NF Habitat certification.

Why ARKENOR

What the local competitor does not cover.

Independent third party

Acceptance measurements kept separate from design: an objective, enforceable certificate for the client.

Drone inspection (DGAC)

Aerial thermography and photogrammetry by a DGAC-registered drone pilot, for hard-to-reach sites in Boulogne-Billancourt.

Upstream → downstream chain

From calculation (ARKEMEP) to measurement (ARKENOR) and independent third-party certification (IRICE, Cofrac 5-0655).

Coverage area

Measurements & diagnostics in Boulogne-Billancourt and the surrounding area.

Our teams travel from Aix-en-Provence to Boulogne-Billancourt and the neighbouring municipalities of the 92 department.

Boulogne-Billancourt
Issy-les-Moulineaux
Sèvres
Meudon
Saint-Cloud
Vanves
Malakoff

FAQ

FAQ, measurements & diagnostics in Boulogne-Billancourt

Yes. ARKENOR conducts acceptance measurements (air permeability, acoustics, ventilation) as an independent third party, separate from the design engineering office, which guarantees the objectivity of the certificate towards the client/developer and the technical inspector.
Yes. RE2020 measurements are carried out under QUALIBAT 8711 (air permeability) and 8741 (ventilation system checking) qualifications, recognised for regulatory certificates at handover.
On-site measurements are scheduled according to the progress of the works and the location. An intermediate air permeability test is slotted in from the weathertight-shell stage; acceptance measurements are programmed before handover. We confirm the date once we receive the works programme and the drawings.
They are the best means of objectively assessing them. A finding measured at handover, compliant with the applicable requirements, places the client/developer in a strong position should a complaint arise later. Conversely, the absence of measurement leaves the question open and makes the case difficult to prove after the fact. On mixed-use schemes, where dwellings, offices and amenities are superimposed, we recommend measuring the most unfavourable configurations rather than an average sample.

Related services

ARKENOR also carries out in Boulogne-Billancourt, as an independent third party:

A project in Boulogne-Billancourt? Let's schedule your acceptance testing.

Sans engagement · Réponse sous 48 h ouvrées · Données confidentielles