Electromagnetic field measurements
Boulogne-Billancourt, Île-de-France

Electromagnetic field measurements in Boulogne-Billancourt: 50 Hz and radiofrequencies, ANFR protocol, calibrated equipment, as an independent third party.

Updated 16 July 2026

Boulogne-Billancourt · Île-de-France

Electromagnetic field measurements in Boulogne-Billancourt.

In Boulogne-Billancourt, the density of the built environment leads to situations where dwellings and building electrical rooms are directly adjacent, a classic configuration of the dense urban fabric and a frequent one during restructuring works. The media and broadcasting activities present in the area add transmission installations whose radiofrequency contribution must be characterised on site. ARKENOR conducts the measurement of electric and magnetic fields at low frequencies and the radiofrequency survey, and delivers an independent third-party report usable for certification.

In Boulogne-Billancourt, electromagnetic field measurement establishes the real exposure of a site objectively: low frequencies at 50 Hz near distribution networks and transformer substations, radiofrequencies around transmitters. It positions the results against the regulatory reference levels and documents the "electromagnetic waves" criterion valued in HQE and NF Habitat certification.

Our services

Electromagnetic field measurements in Boulogne-Billancourt: what we do.

50 Hz electric field (kV/m)

50 Hz magnetic field (µT)

Radiofrequencies 9 kHz to 300 GHz (V/m)

On-site campaign, calibrated equipment (NF EN 50492)

Measurement report and positioning vs reference levels

Coverage area

Electromagnetic field measurements in Boulogne-Billancourt and the surrounding area.

Our teams travel from Aix-en-Provence to Boulogne-Billancourt and the neighbouring municipalities of the 92 department.

Boulogne-Billancourt
Issy-les-Moulineaux
Sèvres
Meudon
Saint-Cloud
Vanves
Malakoff

Scope

ARKENOR carries out on-site electromagnetic field measurements as an independent third party. For design-stage electromagnetic study and engineering, ARKEMEP's engineering practice takes over.

See ARKEMEP's engineering services →

FAQ

FAQ, electromagnetic field measurements in Boulogne-Billancourt

Two distinct domains. In low frequencies (50 Hz), the electric field in kV/m and the magnetic field in µT, associated with distribution networks, transformer substations, rising mains and internal installations. In radiofrequencies, from 9 kHz to 300 GHz, the electric field in V/m, associated with telecommunications transmitters. Each domain has its own protocol and calibrated equipment.
The reference levels come from European recommendation 1999/519/EC, transposed by decree no. 2002-775: 5 kV/m and 100 µT at 50 Hz, and 28 to 61 V/m in radiofrequencies depending on the band. Certification frameworks value more demanding thresholds: 5 V/m and 0.4 µT, then an enhanced tier at 1.5 V/m and 0.2 µT.
No, it is not a general building requirement. It comes into play as an item of evidence within certification frameworks, notably HQE Bâtiment Durable ("electromagnetic waves" theme, formerly target 12) and NF Habitat HQE, where it is a value-adding criterion rather than an absolute prerequisite. We act as an independent third party.