Indoor air quality simulation
La Rochelle, New Aquitaine

Indoor air quality simulation in La Rochelle with INDALO: documenting the IAQ requirements of the HQE, BREEAM and NF Habitat certifications from the design stage.

Updated 16 July 2026

La Rochelle · New Aquitaine

Indoor air quality simulation in La Rochelle.

In La Rochelle, the indoor air quality requirement appears frequently in the public and university schemes driven by the area's low-carbon momentum, alongside energy and carbon targets. The maritime proximity guides the choices of siting and filtration of air intakes, while the occupancy density of teaching premises weighs heavily on the modelled scenarios. The simulation with INDALO estimates the predicted concentrations and documents the requirements of the targeted scheme. It takes place at the design stage, with no on-site air sampling or analysis.

In La Rochelle, the indoor air quality of a new building is decided at the design stage, through two levers: the specification of products according to their emissions health labelling and the design of the ventilation. The simulation estimates the predicted concentrations and produces the technical justification expected by certification schemes, before choices are locked in.

Our services

Indoor air quality simulation in La Rochelle: what we do.

IAQ simulation at design stage (INDALO, IZUBA énergies)

Product specification based on emissions health labelling

Ventilation design and verification

Indoor air quality plan (BREEAM Hea 02 prerequisite)

Justification of HQE and NF Habitat requirements

Coverage area

Indoor air quality simulation in La Rochelle and the surrounding area.

Our teams travel from Aix-en-Provence to La Rochelle and the neighbouring municipalities of the 17 department.

La Rochelle
Aytré
Périgny
Lagord
Châtelaillon-Plage
Rochefort

Scope

The indoor air quality simulation builds on the ventilation design: airflow rates, sweeping principle, filtration and air-intake positioning are all sized by our MEP engineering office.

See ventilation and MEP engineering →

FAQ

FAQ, indoor air quality simulation in La Rochelle

No. Our service is a simulation carried out at the design stage, using the INDALO tool from IZUBA énergies. We carry out no on-site air sampling or analysis. Measurement campaigns, in particular those required by the regulatory monitoring of public-access buildings, fall to accredited bodies and lie outside our scope.
It is there to inform decisions. It estimates the predicted concentrations according to the specified materials, the ventilation system and the occupancy scenarios, and makes it possible to compare variants before choices are locked in. It also produces the technical justification expected by the schemes, including the indoor air quality plan required as a prerequisite by BREEAM Hea 02.
HQE Bâtiment Durable on the sanitary air quality aspect, BREEAM Hea 02 for the IAQ plan required from the design stage, and NF Habitat / NF Habitat HQE on the indoor air profile. On the other hand, schemes that require an on-site measurement before occupancy, such as DGNB SOC1.2 or the WELL preconditions, additionally call for a measurement provider. Requirements depend on the version of the applicable scheme.

A project in La Rochelle? Let's talk.

Sans engagement · Réponse sous 48 h ouvrées · Données confidentielles