Indoor air quality simulation
Valence, AURA

Indoor air quality simulation in Valence with INDALO: documenting the IAQ requirements of the HQE, BREEAM and NF Habitat certifications from the design stage.

Updated 16 July 2026

Valence · Auvergne-Rhône-Alpes

Indoor air quality simulation in Valence.

In Valence, the housing schemes and public facilities likely to pursue certification are designed within a corridor where exposure to transport infrastructure guides the choice of siting of air intakes, and where the mistral influences the actual behaviour of the ventilation. The simulation with INDALO models the predicted concentrations from the emissions of the specified products, the ventilation principle and the occupancy scenarios, and produces the justification expected in the certification file. It takes place at the design stage, with no air sampling or analysis.

In Valence, the indoor air quality of a new building is decided at the design stage, through two levers: the specification of products according to their emissions health labelling and the design of the ventilation. The simulation estimates the predicted concentrations and produces the technical justification expected by certification schemes, before choices are locked in.

Our services

Indoor air quality simulation in Valence: what we do.

IAQ simulation at design stage (INDALO, IZUBA énergies)

Product specification based on emissions health labelling

Ventilation design and verification

Indoor air quality plan (BREEAM Hea 02 prerequisite)

Justification of HQE and NF Habitat requirements

Coverage area

Indoor air quality simulation in Valence and the surrounding area.

Our teams travel from Aix-en-Provence to Valence and the neighbouring municipalities of the 26 department.

Valence
Bourg-lès-Valence
Portes-lès-Valence
Romans-sur-Isère
Guilherand-Granges
Chabeuil

Scope

The indoor air quality simulation builds on the ventilation design: airflow rates, sweeping principle, filtration and air-intake positioning are all sized by our MEP engineering office.

See ventilation and MEP engineering →

FAQ

FAQ, indoor air quality simulation in Valence

No. Our service is a simulation carried out at the design stage, using the INDALO tool from IZUBA énergies. We carry out no on-site air sampling or analysis. Measurement campaigns, in particular those required by the regulatory monitoring of public-access buildings, fall to accredited bodies and lie outside our scope.
It is there to inform decisions. It estimates the predicted concentrations according to the specified materials, the ventilation system and the occupancy scenarios, and makes it possible to compare variants before choices are locked in. It also produces the technical justification expected by the schemes, including the indoor air quality plan required as a prerequisite by BREEAM Hea 02.
HQE Bâtiment Durable on the sanitary air quality aspect, BREEAM Hea 02 for the IAQ plan required from the design stage, and NF Habitat / NF Habitat HQE on the indoor air profile. On the other hand, schemes that require an on-site measurement before occupancy, such as DGNB SOC1.2 or the WELL preconditions, additionally call for a measurement provider. Requirements depend on the version of the applicable scheme.

A project in Valence? Let's talk.

Sans engagement · Réponse sous 48 h ouvrées · Données confidentielles