Electromagnetic field measurements
Poitiers, New Aquitaine

Electromagnetic field measurements in Poitiers: 50 Hz and radiofrequencies, ANFR protocol, calibrated equipment, as an independent third party.

Updated 16 July 2026

Poitiers · New Aquitaine

Electromagnetic field measurements in Poitiers.

In Poitiers, the South Europe Atlantic high-speed line and its catenary supply constitute a low-frequency source specific to electrified rail infrastructure, whose characterisation can only be carried out through on-site measurement. The Futuroscope tertiary hub and the university and hospital establishments also concentrate technical rooms and delivery substations integrated into buildings. ARKENOR carries out the measurement as an independent third party, at low frequencies as well as in radiofrequencies, and delivers a report usable in the certification file.

In Poitiers, electromagnetic field measurement establishes the real exposure of a site objectively: low frequencies at 50 Hz near distribution networks and transformer substations, radiofrequencies around transmitters. It positions the results against the regulatory reference levels and documents the "electromagnetic waves" criterion valued in HQE and NF Habitat certification.

Our services

Electromagnetic field measurements in Poitiers: what we do.

50 Hz electric field (kV/m)

50 Hz magnetic field (µT)

Radiofrequencies 9 kHz to 300 GHz (V/m)

On-site campaign, calibrated equipment (NF EN 50492)

Measurement report and positioning vs reference levels

Coverage area

Electromagnetic field measurements in Poitiers and the surrounding area.

Our teams travel from Aix-en-Provence to Poitiers and the neighbouring municipalities of the 86 department.

Poitiers
Buxerolles
Chasseneuil-du-Poitou
Migné-Auxances
Saint-Benoît
Poitiers-Ouest

Scope

ARKENOR carries out on-site electromagnetic field measurements as an independent third party. For design-stage electromagnetic study and engineering, ARKEMEP's engineering practice takes over.

See ARKEMEP's engineering services →

FAQ

FAQ, electromagnetic field measurements in Poitiers

Two distinct domains. In low frequencies (50 Hz), the electric field in kV/m and the magnetic field in µT, associated with distribution networks, transformer substations, rising mains and internal installations. In radiofrequencies, from 9 kHz to 300 GHz, the electric field in V/m, associated with telecommunications transmitters. Each domain has its own protocol and calibrated equipment.
The reference levels come from European recommendation 1999/519/EC, transposed by decree no. 2002-775: 5 kV/m and 100 µT at 50 Hz, and 28 to 61 V/m in radiofrequencies depending on the band. Certification frameworks value more demanding thresholds: 5 V/m and 0.4 µT, then an enhanced tier at 1.5 V/m and 0.2 µT.
No, it is not a general building requirement. It comes into play as an item of evidence within certification frameworks, notably HQE Bâtiment Durable ("electromagnetic waves" theme, formerly target 12) and NF Habitat HQE, where it is a value-adding criterion rather than an absolute prerequisite. We act as an independent third party.

A project in Poitiers? Let's talk.

Sans engagement · Réponse sous 48 h ouvrées · Données confidentielles