Measurements & diagnostics
Chambéry, Acoustics · Air permeability · Ventilation · EPC · Drone
In Chambéry, ARKENOR carries out the regulatory acceptance measurements of buildings — air permeability (RE2020), acoustics, ventilation, energy performance certificate — as an independent third party, with compliant certificates.
Updated 21 July 2026
Chambéry · Auvergne-Rhône-Alpes
Regulatory measurements & diagnostics in Chambéry.
Prefecture of the Savoie, Chambéry occupies a valley cluse that concentrates infrastructure, housing and activity within a narrow corridor, a configuration that places a large part of the territory in high noise exposure. At handover, verification of façade sound insulation therefore takes on greater importance than average. The proximity of an energy research hub also raises the level of expectation of local clients and developers. In Chambéry and across the Savoie we carry out regulatory acceptance measurements, as an independent third party.
Our measurements
Six families of measurements & diagnostics in Chambéry.
RE2020 air permeability testing
QUALIBAT 8711Airtightness testing (Q4Pa-surf air permeability): an intermediate test at the weathertight-shell stage to correct defects before lining, and a regulatory RE2020 acceptance test on the finished building.
Acceptance acoustic testing
NF EN ISO 16283Airborne sound insulation (DnT,A / DnT,A,tr), impact sound (L'nT,w), equipment noise and reverberation: verification of the NRA housing requirements and the ERP order, carried out as an independent third party.
RE2020 ventilation airflow testing
QUALIBAT 8741Functional checking of ventilation systems (airflow rates, pressure drops, ductwork airtightness) required by RE2020 at the handover of new dwellings.
Housing and commercial energy performance certificate (DPE)
certified assessorLegally binding energy performance certificate (DPE), issued by a certified assessor, for sale, letting and monitoring under the tertiary-sector decree.
Drone aerial inspection
DGAC drone pilotInspection of roofs and façades, aerial thermography, photogrammetry and mapping by drone (DGAC-registered drone pilot), on sites that are difficult to access.
Electromagnetic field (EMF) measurements
NF EN 50492Low frequencies at 50 Hz (electric field kV/m, magnetic field µT) and radiofrequencies from 9 kHz to 300 GHz (V/m), following the UTE/NF C99-132 and ANFR protocols. A criterion recognised in HQE and NF Habitat certification.
Why ARKENOR
What the local competitor does not cover.
Independent third party
Acceptance measurements kept separate from design: an objective, enforceable certificate for the client.
Drone inspection (DGAC)
Aerial thermography and photogrammetry by a DGAC-registered drone pilot, for hard-to-reach sites in Chambéry.
Upstream → downstream chain
From calculation (ARKEMEP) to measurement (ARKENOR) and independent third-party certification (IRICE, Cofrac 5-0655).
Coverage area
Measurements & diagnostics in Chambéry and the surrounding area.
Our teams travel from Aix-en-Provence to Chambéry and the neighbouring municipalities of the 73 department.
FAQ
FAQ, measurements & diagnostics in Chambéry
Other locations
Measurements & diagnostics across the region.
Related services
ARKENOR also carries out in Chambéry, as an independent third party:
A project in Chambéry? Let's schedule your acceptance testing.